Rated Voltage | 48 Volts |
Rated For Motors | Up To 1000 Watts |
Maximum Current | 40 Amps |
Rated For Chargers | Up To 3 Amps |
Under Voltage Protection | 42 Volts ± 1.0 Volt |
Recommended Fuse or Circuit Breaker Size | 50 Amps |
Dimensions (including mounting tabs) | 4" Long x 2-5/8" Wide x 1-1/2" High |
Labeled Connectors: The two
identical connectors with black and red wires going to them are
labeled for easy identification. Under Voltage Battery Protection:
When the battery pack falls below a specific Voltage the controller
turns the motor off preventing over discharging of the battery pack
which extends the lifespan of the battery pack. (The cutoff value is
approximately 42 Volts ± 1.0 Volt) |
*Power Connector
Mating Connector Item # CNX-50 |
|
|
Motor Connector
Mating Connector Item # CNX-50 |
Required Connection |
|
Throttle
Connector
Mating Connector Item # CNX-52 |
Required Connection |
|
Key or
Power Switch Blue & Blue Disconnected = Power Off Blue & Blue Connected = Power On Mating Connector Item # CNX-51 |
Required Connection |
|
Speed Selection Switch
All Wires Disconnected = High Black & Red Connected = Medium Black & Yellow Connected = Low Mating Connector Item # CNX-52 |
~Optional Connection |
|
Reverse
Switch Connector Black & Yellow Connected = Motor Reverse Mating Connector Item # CNX-51 |
~Optional Connection |
|
Charger Port Connector
|
~Optional Connection |
|
Brake
Switch Connector Green & Black Connected = Motor Off and Brake Light On Mating Connector Item # CNX-51 |
~Optional Connection |
|
Brake
Light Connector
|
~Optional Connection |
|
Power
Indicator Connector
|
~Optional Connection |
*The power connector
should be the last connection made. *Fuse or circuit breaker protection should be installed between speed controller and battery pack. ~Optional Connections do not need to be hooked up for the speed controller to operate. |