Speed Controller SPD-481000B Installation and Wiring |
|
Rated Voltage | 48 Volts |
Rated For Motors | Up To 1000 Watts |
Maximum Current | 30 Amps |
Rated For Chargers | Up To 3 Amps |
Conversion Efficiency | 95% |
Under Voltage Protection | 42 Volts |
Recommended Fuse/Circuit Breaker Size | 35 Amps |
Dimensions | 4-3/8" x 2-3/4" x 1-1/2" |
Under Voltage Battery Protection:
When the battery pack falls below a specific Voltage the controller
turns the motor off preventing over discharging of the battery pack
which extends the battery packs lifespan. (The cutoff value is
approximately 42 Volts ± 0.5 Volts) Motor Cut-Off During Braking: When the brakes are engaged the brake switch signals the controller to turn off the motor. |
*Power Connector |
|
Motor
Connector Blue = Positive Yellow = Negative Mating Connector Item # CNX-50 |
Required Connection |
Throttle
Connector Mating Connector Item # CNX-52 |
Required Connection |
Key
Switch Connector Mating Connector Item # CNX-51 |
Required Connection |
Charger Port Connector Red = Positive Black = Negative Mating Connector Item # CNX-51 |
~Optional Connection |
Brake Switch Connector Mating Connector Item # CNX-51 |
~Optional Connection |
Brake Switch Connector Mating Connector Item # CNX-51 |
~Optional Connection |
Brake
Light Connector
Mating Connector Item # CNX-51 |
~Optional Connection |
Power Light Connector
Mating Connector Item # CNX-51 |
~Optional Connection |
Sport Switch Connector
Mating Connector Item # CNX-51 |
~Optional Connection |
*The power connector