Speed Controller SPD-361000B Installation and Wiring |
|
Rated Voltage | 36 Volts |
Rated for Motors | Up To 1000 Watts |
Maximum Current | 32 Amps |
Rated for Chargers | Up To 3 Amps |
Under Voltage Protection | 31 Volts ± 1 Volt |
Recommended Fuse or Circuit Breaker Size | 40 Amps |
Dimensions | 2-7/8" Wide x 1-1/2" High x 4-3/4" Long |
Wire Length | 4 Inches |
Under Voltage Battery Protection:
When the battery pack falls below a specific Voltage the controller
turns the motor off preventing over discharging of the battery pack
which extends the battery packs lifespan. (The cutoff value is
approximately 31.0 Volts ± 1.0 Volt) Motor Cut-Off During Braking: When the brakes are engaged the brake switch signals the controller to turn off the motor. |
*Power Connector |
Required Connection |
Motor
Connector Blue = Positive Yellow = Negative Mating Connector Item # CNX-50 |
|
Throttle Connector
Requires 3-Wire Standard Throttle
Red = + 5 Volts
Mating Connector Item # CNX-52 |
Required Connection |
Key
Switch Connector Wires Disconnected = Power Off |
Required Connection |
Battery Charger Connector Black = Negative
Red = Positive |
~Optional Connection |
Power
Light Connector Black = Negative
Pink = +36 Volts |
~Optional Connection |
Brake
Lever Switch Connector Wires Disconnected = Motor On Wires Connected = Motor Off
Mating Connector Item # CNX-51 |
~Optional Connection |
Brake
Light Connector Red = +36 Volts
Yellow = Negative |
~Optional Connection |
*The power connector
should be the last connection made. *Fuse or circuit breaker protection is required between speed controller and battery pack. ~Optional Connections do not need to be hooked up for the speed controller to operate. |